11 research outputs found

    The Vulnverability Cube: A Multi-Dimensional Framework for Assessing Relative Vulnerability

    Get PDF
    The diversity and abundance of information available for vulnerability assessments can present a challenge to decision-makers. Here we propose a framework to aggregate and present socioeconomic and environmental data in a visual vulnerability assessment that will help prioritize management options for communities vulnerable to environmental change. Socioeconomic and environmental data are aggregated into distinct categorical indices across three dimensions and arranged in a cube, so that individual communities can be plotted in a three-dimensional space to assess the type and relative magnitude of the communities’ vulnerabilities based on their position in the cube. We present an example assessment using a subset of the USEPA National Estuary Program (NEP) estuaries: coastal communities vulnerable to the effects of environmental change on ecosystem health and water quality. Using three categorical indices created from a pool of publicly available data (socioeconomic index, land use index, estuary condition index), the estuaries were ranked based on their normalized averaged scores and then plotted along the three axes to form a vulnerability cube. The position of each community within the three-dimensional space communicates both the types of vulnerability endemic to each estuary and allows for the clustering of estuaries with like-vulnerabilities to be classified into typologies. The typologies highlight specific vulnerability descriptions that may be helpful in creating specific management strategies. The data used to create the categorical indices are flexible depending on the goals of the decision makers, as different data should be chosen based on availability or importance to the system. Therefore, the analysis can be tailored to specific types of communities, allowing a data rich process to inform decision-making

    Examining Nanoparticle Assemblies Using High Spatial Resolution X-ray Microtomography

    Get PDF
    An experimental system has been designed to examine the assembly of nanoparticles in a variety of process engineering applications. These applications include the harvesting from solutions of nanoparticles into green parts, and the subsequent sintering into finished components. The system is based on an x-ray microtomography with a spatial resolution down to 5 mum. The theoretical limitations in x-ray imaging are considered to allow experimental optimization. A standard nondestructive evaluation type apparatus with a small focal-spot x-ray tube, high-resolution complementary metal oxide semiconductor flat-panel pixellated detector, and a mechanical rotational stage is used to image the static systems. Dynamic sintering processes are imaged using the same x-ray source and detector but a custom rotational stage which is contained in an environmental chamber where the temperature, atmospheric pressure, and compaction force can be controlled. Three-dimensional tomographic data sets are presented here for samples from the pharmaceutical, nutraceutical, biotechnology, and nanoparticle handling industries and show the microscopic features and defects which can be resolved with the system.</p

    Examining nanoparticle assemblies using high spatial resolution x-ray microtomography

    No full text
    An experimental system has been designed to examine the assembly of nanoparticles in a variety of process engineering applications. These applications include the harvesting from solutions of nanoparticles into green parts, and the subsequent sintering into finished components. The system is based on an x-ray microtomography with a spatial resolution down to 5 m. The theoretical limitations in x-ray imaging are considered to allow experimental optimization. A standard nondestructive evaluation type apparatus with a small focal-spot x-ray tube, high-resolution complementary metal oxide semiconductor flat-panel pixellated detector, and a mechanical rotational stage is used to image the static systems. Dynamic sintering processes are imaged using the same x-ray source and detector but a custom rotational stage which is contained in an environmental chamber where the temperature, atmospheric pressure, and compaction force can be controlled. Three-dimensional tomographic data sets are presented here for samples from the pharmaceutical, nutraceutical, biotechnology, and nanoparticle handling industries and show the microscopic features and defects which can be resolved with the system

    Examining Nanoparticle Assemblies Using High Spatial Resolution X-ray Microtomography

    No full text
    An experimental system has been designed to examine the assembly of nanoparticles in a variety of process engineering applications. These applications include the harvesting from solutions of nanoparticles into green parts, and the subsequent sintering into finished components. The system is based on an x-ray microtomography with a spatial resolution down to 5 mum. The theoretical limitations in x-ray imaging are considered to allow experimental optimization. A standard nondestructive evaluation type apparatus with a small focal-spot x-ray tube, high-resolution complementary metal oxide semiconductor flat-panel pixellated detector, and a mechanical rotational stage is used to image the static systems. Dynamic sintering processes are imaged using the same x-ray source and detector but a custom rotational stage which is contained in an environmental chamber where the temperature, atmospheric pressure, and compaction force can be controlled. Three-dimensional tomographic data sets are presented here for samples from the pharmaceutical, nutraceutical, biotechnology, and nanoparticle handling industries and show the microscopic features and defects which can be resolved with the system.</p

    A novel batch crystalliser for in situ monitoring of solution crystallization using energy dispersive x-ray diffraction

    No full text
    In situ X-ray diffraction monitoring of crystallization from solution is often hampered by a combination of the rather low levels of crystallized solid (typically 5 to 20 wt ) and the large background scattering that arises from the solution phase. In this work, we have attempted to overcome these limitations, first, by using high intensity dispersive X-rays available at the Synchrotron Radiation Source, Daresbury Laboratory, UK, and second by designing a novel batch classifying crystallizer. This crystallizer was designed to maximize the weight fraction of solid presented to the probe beam. In this configuration, solution crystallizations generating between 2 and 30 wt of solids were monitored successfully. Three preliminary studies describe the application of this equipment to the simple real time monitoring of a crystallization event, the interconversion of two polymorphic crystalline forms, and the orientation of crystals in the fluid flow of the crystallizer
    corecore